

ViscoFluid RR 8XX
high Range superplasticizer with Excellent Slump Keeping Properties for Self Compacting Concrete
ViscoFluid RR 8XX acts by surface adsorption on cement particles producing sterical hindrance as well as electrostatic repulsion resulting in higher dispersion, flow and retention providing the following beneficial properties:
Self-compacting concrete (SCC) has high impermeability and strength due to extremely high water reduction shrinkage and creep characteristics.
Excellent flowability resulting in minimal placing and compacting efforts
Slower rates of carbonation and chloride, especially silica fume or pozzolanic products, are used for a reasonable cost/performance ratio.
It does not contain chloridesor or other steel corrosion-promoting ingredients; therefore, it may be used for Reinforced and pre-stressed concrete construction.




Better, Faster, Cheaper

Description
- ViscoFluid RR 8XX is a third generation, high performance, dual action superplasticizer, based on Sika’sown ViscoCrete® technology, for the production of self-compacting concrete.
Suitable for use in hot and tropical climatic conditions.
Advantages
- ViscoFluid RR 8XX acts by surface adsorption on cement particles producing sterical hindrance as well as electrostatic repulsion resulting in higher dispersion, flow and retention providing the following beneficial properties
Self-compacting concrete (SCC) high impermeability and strength due to extremely high water reductionImproved shrinkage and creep characteristics Excellent flowability resulting in minimal placing and compacting ef forts Slower rate of carbonation and chloride ingressspeciallywhen silicafume or pozzolanic productsare usedVery good cost / performance ratio there fore may be used for Reinforced and pre-stressed concrete construction
Usage
Site mixed and ready-mix concrete
During hot weather for the production of concrete with extended transportation or placing times
Concrete requiring retained workability for an extended periodTextured surface finish Concrete with extremely high water reductionSelf compacting concrete especially where congested steel reinforcement is encountered or for slim elements requiring a high standard of surface finish.
high performance
high strength concrete
high water reduction and excellent flowability have a positive influence on the above mentioned applications.
Overview
Overview
Sustainability / Certificates / Compliance
-
Conforms to the requirements of BS EN 934-2 Table 2
-
DoP 94867427, certified by Factory Production Control Body 0120 and provided with the UKCA mark
Product Information
Composition
Aqueous solution of modified New Generation Polyelectrolytes Based co-polymer.
Shelf life
12 monts From date of Production if stored properly
Storage conditions
Store in its original, sealed, and undamaged packaging in a dry environment at temperatures between +5°C and +50°C before use, ensure the product is well mixed for optimal performance.
Density
1.06 kg/l +/- 3% (+25°C)
Total chloride ion content
Nil(EN 934-2)
Packaging
210 Liters drum, 1000 Liters IBC or bulk supply in tanker
Colour
Clear to light yellow liquid
Moisture Testing Method
Residual Humidity Spec
Thermal Conductivity (W/mK)
Flexural Strength 28 days
Compressive Strength 28 days (N/mm²)
Drying Time (days)
Application Temp Range
+5°C to +50°C
pH Value
5 ± 0.1
-
Dispensing
This is a ready-to-use admixture that should be added to the concrete as a separate component. For the best results, add it to the concrete mix immediately after the first 80% of the mixing water has been introduced—when all solids are properly wetted. Avoid adding the admixture directly to dry aggregates.
Compatibility
To ensure compatibility among products, please reach out to our technical team. We’re here to help!
Recommended dosage
The recommended dosage ranges from 0.3% to 2. 0% by weight of the binder or 0.13% to 0.2% by weight of the total mix mass. However, the exact dosage may vary based on mix design, raw materials, climatic conditions, and specific concrete requirements. It is essential to conduct trial mixes to determine the optimal dosage for your application.
Concreting guidance
Follow standard best practices for concrete production and placement, adhering to relevant industry standards. Proper curing of fresh concrete is essential, especially in high temperatures, to prevent plastic and drying shrinkage.
The information contained in this document is, in any case, only indicative and must be confirmed by exhaustive practical applications before using the product, ensuring that the use is suitable for the intended use. However, it assumes any responsibility that may arise from its use. For further information, see the updated Technical Data Sheet.
The information contained in this document is, in any case, only indicative and must be confirmed by exhaustive practical applications before using the product, ensuring that the use is suitable for the intended use. However, it assumes any responsibility that may arise from its use. For further information, see the updated Technical Data Sheet.
Compatibility
To ensure compatibility among products, please reach out to our technical team. We’re here to help!
Storage conditions
Store in its original, sealed, and undamaged packaging in a dry environment at temperatures between +5°C and +50°C before use, ensure the product is well mixed for optimal performance.
Storage conditions
Store in its original, sealed, and undamaged packaging in a dry environment at temperatures between +5°C and +50°C before use, ensure the product is well mixed for optimal performance.
Contact Us
Ubora Office Tower - Business Bay
Dubai - Emirati Arabi Uniti
© 2025 by Bellavita-Costa Consulting
